Embodied Carbon In BIM.
Embodied carbon is the greenhouse gas released to make, transport and install a building's materials. A BIM model already holds most of what is needed to estimate it, early enough to change the design.
Embodied Carbon Is Spent Before The Building Opens.
A building's carbon has two parts. Operational carbon comes from running it, mostly heating, cooling and electricity. Embodied carbon is already spent by the time the doors open: the emissions of producing the concrete, steel, glass and timber, moving them to site and putting them in place.
Embodied carbon is usually reported in kilograms of carbon dioxide equivalent, written kgCO2e, which counts other greenhouse gases in terms of carbon dioxide. The larger the quantity of a carbon-heavy material, the larger the figure.
Quantity Multiplied By A Carbon Factor.
The method is simple. The care goes into the inputs: an estimate is only as good as the quantities in the model and the factors chosen, so both should be stated alongside any figure.
- Take the quantity of each element from the model, such as the volume of a slab, the area of a facade or the length of a pipe
- Find the carbon factor for its material, the kgCO2e per unit of that material, often from an Environmental Product Declaration (EPD) or a published database
- Multiply the two for each element
- Add the elements up by floor, by discipline, by material or for the whole building
The Decisions That Matter Most Are The Earliest.
Structure, foundations and facade usually carry most of a building's embodied carbon, and they are fixed early. Measuring at concept and design stage lets the team compare a timber frame with a concrete one, or a lighter facade with a heavier one, while the change is still a drawing. After construction starts, the same insight can only be reported.
Which Part Of The Life Cycle Is Counted.
Building life cycle assessment splits a building's life into stages, set out in the European standard EN 15978 and used in many other countries. Embodied carbon covers every stage except the energy and water used to run the building.
Where The Factors Come From.
The best factor is the one for the actual product, from its Environmental Product Declaration (EPD). EPDs follow the standards EN 15804 and ISO 14025 and state the product's carbon per declared unit, such as per kilogram or per cubic metre.
Early in design the exact product is not chosen yet, so teams use generic factors from national or industry databases. What matters most is consistency: two design options compared with factors from different sources tell you about the sources, not about the design. Record which factor was used for each material, and update it when a product is chosen.
What Makes Model-Based Figures Wrong.
- Elements that overlap in the model are counted twice
- Items that are not modelled, such as reinforcement, fixings or finishes, are missing from the total
- Material names in the model do not match the factor list, so elements are left out or matched wrongly
- Options are compared with different scopes, such as one including the basement and one without
- Results per square metre use different definitions of floor area
The Usual Hot Spots.
In many buildings the structure and foundations carry the largest share of upfront embodied carbon, mainly through concrete and steel, with the facade often next. That is why the most effective changes are structural: shorter spans, fewer transfer structures, lower-cement concrete mixes, timber where it suits the building, and keeping an existing structure instead of replacing it.
These are decisions for concept and early design. A model-based estimate makes their effect visible while they can still be made.
DesignX ESG.
DesignX ESG reads material quantities from the IFC model, estimates embodied carbon per element, floor, discipline and material with factors your team can set, and lets you compare design options as versions of the same project.
Common Questions.
What Is DesignX ESG?
DesignX ESG measures the sustainability of a building from its design model. It reads material quantities from the IFC model, estimates embodied carbon per element, floor, discipline and material, and summarises the result for the design team, the client and investors.
How Is Embodied Carbon Measured From A BIM Model?
Embodied carbon is the greenhouse gas released to make and install a building's materials. From the model, SpaceDesignX reads the quantity of each element, such as volume or area, and applies a carbon factor for its material. The result is an estimate that is only as good as the quantities in the model and the factors used.
Can We Compare The Carbon Of Design Options?
Yes. Import each option or revision as a version of the project, then compare the totals and the elements that carry the most carbon. Changes can be tested while the design can still move.
Who Uses The ESG Results?
The design team uses them to choose lower-carbon options, the client to follow the targets, and investors to see a clear summary. The same figures are shared, so nobody works from a different spreadsheet.
See Your Own Model In SpaceDesignX.
Send us a model you know well. We will walk you through it live in the products that fit your work: approvals, clash detection, defects and handover, or carbon.